Troubleshooting
Busy Bee Wastewater doesn't believe the customer should have to attend to any problems with their aerated wastewater treatment system (AWTS) and they only need contact us to instigate a call-out, however we also realise some people prefer to check what they can themselves and avoid an unnecessary call-out charge.
Below is a general troubleshooting guide for those who would prefer to do a preliminary investigation themselves.
Please note: For single alarm light systems both water and air alarm problems may be relevant.
Problem |
Possible Cause |
|
| Water & air alarm on |
Circuit breaker tripped off |
Check circuit breaker |
| Water alarm on |
Blocked irrigation filter |
Turn off power to AWTS, clean irrigation filter, turn power back on to AWTS and wait 1 hour before checking the alarm again |
Water alarm on |
Kinked irrigation line |
Check entirety of irrigation line for kinks |
| Water alarm on |
Recent interruption to power supply |
Wait 1 hour and check alarm again |
| Water alarm on |
Hydraulic overload eg. party, large spa bath emptied |
Wait 1 hour and check alarm again |
| Water alarm on |
Ground water entering system in heavy rain |
Wait till 1 hour after heavy rain eases and check alarm again. |
| Air alarm on |
Circuit breaker tripped off |
Check circuit breaker |
| Odour from AWTS |
Circuit breaker/s tripped off |
Check circuit breaker/s |
Please remember we are available 24hrs 365 days per year should you need to contact us.